Working together

Know what you’re buying.

A useful engagement starts with a clear need and an agreed result. Here is what to expect before you commit to development or a security assessment.

The first conversation

We discuss the business goal, current system, constraints, and any deadline. You don’t need a finished spec.

The written scope

We agree on the work, exclusions, deliverables, acceptance criteria, responsibilities, and pricing before it begins.

Review and next steps

Discuss the delivered software or findings with the engineers responsible. Handoff, follow-up, and retesting are defined in the scope.

Make the deliverable concrete

What useful work leaves you with.

Excerpts from the documents and reports our clients receive.

Evidence pack · SummarySample

Example Health Partners: evidence pack, production

Environment: production. Period: last 90 days. Every file in the pack carries its SHA-256 hash in the pack’s manifest.

Verify

Verification run, this environment’s servers:

  • 0 fail
  • 0 error
  • 1 warn
  • 133 pass
  • 10 n/a

Quarterly restore test

Server
Database server, from the off-site copy
Result
Passed
Elapsed
8 min 18 s across all stages; the restore stage itself took 7 min 24 s
Log replayed
95 write-ahead log segments, to the chosen recovery point
Checked afterward
Table counts against the live database; one table differs by what 14 commits after the recovery point account for
Live database
Not restarted, not in recovery, its own backup check passing

Backups

Database server

  • backup.offsite_existsOff-site repository holds 13 full and 77 differential backupspass
  • backup.offsite_encryptedOff-site repository is encrypted (aes-256-cbc)pass
  • backup.offsite_freshNewest off-site backup is 3 hours old (nightly, 02:15 UTC)pass
Show moreShow less

Backups, continued

  • backup.offsite_verifiedNewest backup downloaded, checksum matched and decryptedpass
  • backup.offsite_pausedWrite-ahead log archiving reaches the off-site repository; the watchdog is runningpass
  • backup.secrets_not_inlineBackup credentials are not in a readable configpass
  • backup.restore_testedRestore test passed 20 days before this packpass

Security updates (fix records)

Last 90 days: 7 scheduled update runs across the production servers. 6 applied updates and 1 found nothing to apply. Each run had a recorded approval before it started.

Quarterly access review

4 accounts reviewed by a named Blue Axis engineer: 3 kept, 1 marked for removal (no sign-in in 90 days). Every account signs in with a second factor. Machine accounts are listed separately.

Emergency console (break-glass) uses

  • Application serverDetected by the scheduled check. Reviewed 26 hours after detection. Authorized: yes.reviewed

Why: the gateway agent on the server stopped after the provider’s maintenance restart. Follow-up: an alert when that agent stops (added).

Incident response tabletop

Final after-action record on file, held within the last 12 months.

Risk analysis

Current risk analysis record on file.

Request a redacted sample evidence pack →
Evidence pack · Emergency access procedureSample

Emergency access (break-glass) procedure

How Blue Axis reaches a server when the normal way in is down, who can do it, and how every use is caught and reviewed. This page is part of your evidence pack. The uses on record are listed in the pack’s summary.

On a normal day

Every person signs in through one sign-on gateway, with their own named account and multi-factor sign-in. Sessions are recorded. No server accepts a password over the network.

Each server has one emergency account. It has no usable password. Nobody at Blue Axis, at your company, or at the infrastructure provider knows a password for it, because none exists. Our automated checks confirm that on every run.

When it is used

Only when the sign-on gateway or the network path to a server is down and the server needs hands on it before that can be repaired. It is never used for routine work, and never to save time.

Who can use it

Only Blue Axis engineers who hold access to the infrastructure provider account for your environment. Your staff, your developers, and anyone holding only a gateway account cannot.

What happens

  1. The engineer asks the infrastructure provider to issue a new one-time password for that one server.
  2. The provider applies it by restarting the server. A password cannot be issued without that restart.
  3. The provider shows the password once. It goes into Blue Axis’s emergency vault for your environment, and is never sent by email or chat.
  4. The engineer signs in at the provider’s console for that server. The password works there and nowhere else. It cannot be used over the network.
Show moreShow less

Why it cannot happen quietly

  • It needs the infrastructure provider account, which is separate from every server and from the gateway.
  • It restarts the server. A restart interrupts service and is recorded in the server’s own logs.
  • The server’s own logs record the password change and the console sign-in. Our checks read those logs on a schedule, detect any use within 24 hours, and alert an engineer.
  • A log that is missing, cut short, or does not reach back to the previous check is reported as an error. It is never treated as “no use”.
  • While a usable password exists on the emergency account, our checks fail. They keep failing until it is removed.

Afterward

The engineer removes the password, restarts the server once more, and runs the checks again. They must show the emergency account has no usable password before the work is closed.

How each use is reviewed

Every detected use is reviewed within 2 business days. The review records what happened, when, on which server, and whether it was authorized. A use that was not authorized opens a security incident, and you are notified as your agreement with us sets out. Each detection and each review is kept in this evidence pack, including test uses and anything found from before we managed the server.

What this does not cover

  • Actions inside the infrastructure provider that leave nothing on the server, such as the provider copying a disk. Those are governed by the provider’s Business Associate Agreement.
  • Someone who already has full control of a server and alters single log entries by hand. Removing or cutting whole logs is caught. Careful edits inside a log are not.
Evidence pack · Data-flow diagramSample

Where patient data lives and moves

Data flow for one client environment Patients and clinic staff reach the production application server over HTTPS. Blue Axis engineers reach servers only through the access gateway, with sign-in, a second factor and recorded sessions. The client has one private network with a gateway tier, a staging tier and a production tier. Staging and production never connect to each other. Application servers are public on web ports only; database servers are never public. Encrypted backups are copied off-site to a separate backup provider. Data is stored in United States data centers. Patients and clinic staffWeb browser Blue Axis engineersNamed accounts PRIVATE NETWORK One per client Access gateway (gateway tier)Sign-in, second factor, recorded sessions Sign-in and second factor HTTPS PRODUCTION TIERApplication serverPublic on web ports onlyDatabase serverNever public STAGING TIERApplication serverPublic on web ports onlyDatabase serverNever public Staging and production never connect. Engineer sessions from the gateway are recorded. Data is stored in United States data centers. Encrypted backups Encrypted backups Off-site backup providerEncrypted copies, separate provider
Patients and clinic staff
Reach the application over HTTPS. Application servers accept web ports only.
Blue Axis engineers
Reach servers only through the access gateway: their own named account, a second factor, every session recorded.
Staging and production
Separate tiers inside the client’s private network. They never connect to each other.
Database servers
Never public: no route reaches them from the internet.
Backups
Encrypted, then copied off-site to a separate provider. Data is stored in United States data centers.
Security assessment · FindingsSample

FINDING 03 / ACCESS CONTROL

A signed-in patient can open another patient’s appointment record.

Severity
High Any patient account can do it with an ordinary browser, and the record holds health information.
Application
Fernway Scheduling, a patient booking application for a healthcare clinic
Affected area
The patient web app’s appointment detail view, and the API request behind it that returns one appointment by its number.
How it was found
Manual testing with two patient accounts created for the assessment, A and B. Signed in as A, we opened one of A’s appointments, then changed the appointment number in the request to one of B’s.
Evidence
The server returned B’s appointment in full: date and time, clinic location, provider, and visit reason. We repeated it three times with different appointments. The captured request and response, with test patient details masked, are in the report appendix. The automated scan of the same request did not flag it.
Show moreShow less
Impact
Any patient can read other patients’ appointments, including the visit reason. Appointment numbers are sequential, so records can be read in bulk by counting. The application logs these requests like normal use, so the clinic could not tell afterward whose records were read.
The fix
On the server, before returning an appointment, check that it belongs to the signed-in patient, or that the user is clinic staff with access to that location. Answer “not found” both for appointments that do not exist and for ones the user may not see. The change and cancel actions share the same lookup and need the same check.
How the fix is retested
Once the fix is on staging, we repeat the original requests with both test accounts, then try the change and cancel actions on B’s appointments, and the same requests from a staff account at another location. The finding closes when every request for someone else’s appointment is refused and A can still use their own. The retest result is added to this report.

For a security assessment

Expect the agreed scope and limitations, an executive summary, validated findings with impact and evidence, remediation priorities, and a technical readout. Retesting belongs in the scope too.

Cost & timing

Start with the scope, then agree on the commitment.

Development depends on the existing system, integrations, complexity, and the size of the next release. Assessment scope depends on the applications, environments, access, and depth of testing.

Tell us about any budget or deadline early. We discuss the options and agree on cost, schedule, and deliverables before work starts.

Discuss scope and budget →

Before you start

Questions worth asking.

Use these prompts with your team. You don’t need to submit answers or assign your system a score.

  1. 01

    Where does the work slow down?

    Look for repeated manual entry, waiting between teams, or changes that take longer than expected.

    Explore integrations →
  2. 02

    What would a useful first release change?

    Name the task, decision, or customer experience you want to improve. A smaller first scope can make the next step clearer.

    Explore development →
  3. 03

    Can the system change with the business?

    Consider whether the application is documented, maintainable, and understood by more than one person.

    Explore modernization →
  4. 04

    What can your AI application reach?

    List the data and tools it can access. Ask whether those boundaries have been tested with untrusted inputs.

    Explore AI security →
  5. 05

    What evidence is the customer asking for?

    Separate the requested assessment, controls, and documentation so the engagement addresses the actual requirement.

    Explore readiness support →

Let’s talk

What’s standing between you and the next signed contract?

Tell us about the review, the deadline, or the system. You don’t need a finished spec. You’ll talk to the engineer who does the work.